HEF Hall Effect Pickup
Installation and Technical Data Guide
AW Flow Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Rev 06/06
Description:
The HEF is a Hall Effect sensor which is compatible with the Aluminum, 303 Stainless Steel and 316 Stainless
Steel body JV-CG and JV-KG series of flow meters. The sensor detects the rotation of the flow meter’s gears
and emits a frequency signal proportional to flow. The output signal is a square wave pulse which has a duty
cycle of approximately 50%.
HEF signal outputs are protected with a self-resetting fuse. This fuse has a 50mA nominal trip point. When a
trip occurs, turn off power to the sensor and remove output load to reset fuse.
The HEF sensor has two different output configurations: HEF-A or HEF-AA for a sinking output and HEF-B or
HEF-BB for sourcing output.
Installation:
• Ensure that the flowmeter sensor cavity is free of debris prior to installing pickup
• Make sure the sensor mounting screws line up with the mounting holes. If they do not, remove and rotate
the sensor 180°
NOTE: WIRING SHOULD BE INSTALLED BY A QUALIFIED INSTRUMENTATION TECHNICIAN
Pin Number Wire Color
Supply Voltage: 6 Red
Ground: 5 Black
Signal: 4 White
AW wiring color code:
Pin Number HEF-A / -AA HEF-B / -BB
1 NC NC
2 NC NC
3 NC NC
4 Output Output
5 Ground Ground
6 Supply Supply
Electrical Connection for Pin Connector
Part number configuration:
HEF sensors can be used wih all Aluminum, 303 Stainless
Steel and 316 Stainless Steel body flow meters
JV-CG 01, 10, 15, 20 & 30
JV-KG 12, 20 & 30
JV-60CG & JV-60KG ONLY
Pinout looking at male connector on sensor
HEF-A, HEF-B
HEF-AA, HEF-BB
Comentarios a estos manuales